Reference
IT equipment logistics reference data
Rules, limits and standards that govern moving IT equipment, each with its primary source.
This page collects the official rules, limits and standards that govern moving enterprise IT equipment in the United States: driver hours, truck weight, cargo securement, carrier liability, battery shipping, environmental ranges, media sanitization, seals, facility codes and recovery terms. Each figure links to the primary source it was checked against.
Last verified: October 2026
Regulations and standards change. Confirm any figure against the cited source before you rely on it, and treat this page as a reference, not legal or compliance advice. Terms used here are defined in the IT logistics glossary.
How long can a truck driver drive, and how heavy can the truck be?
A property-carrying driver may drive 11 hours inside a 14-hour on-duty window after 10 hours off duty, needs a 30-minute break after 8 hours of driving, and stops at 60 or 70 on-duty hours per week. On the Interstate, gross vehicle weight is capped at 80,000 pounds.
| Item | Figure or rule | Source | Notes |
|---|---|---|---|
| Daily driving limit | 11 hours of driving, after 10 consecutive hours off duty | 49 CFR 395.3 | 395.3(a)(1) and (a)(3)(i). Applies to property-carrying commercial motor vehicles. |
| On-duty window | No driving after the 14th consecutive hour after coming on duty | 49 CFR 395.3 | 395.3(a)(2). The window does not pause for breaks. |
| Rest break | 30 consecutive minutes once 8 hours of driving have passed | 49 CFR 395.3 | 395.3(a)(3)(ii). Off-duty, sleeper berth or on-duty not-driving time counts. Short-haul exceptions in 395.1(e) apply. |
| Weekly on-duty limit | 60 hours in 7 consecutive days, or 70 hours in 8 consecutive days | 49 CFR 395.3 | 395.3(b). The 70/8 limit applies when the carrier operates every day of the week. |
| Weekly restart | 34 or more consecutive hours off duty | 49 CFR 395.3 | 395.3(c). Starts a new 7- or 8-day period. |
| Gross vehicle weight, Interstate System | 80,000 lb maximum | 23 CFR 658.17 | 658.17(b). A lower limit applies where the Bridge Gross Weight Formula dictates. |
| Axle weights, Interstate System | 20,000 lb single axle; 34,000 lb tandem axle | 23 CFR 658.17 | 658.17(c) and (d). |
Related: Interstate IT shipments: hours-of-service, weight and carrier authority Relocation timeline estimator
What does federal cargo securement require for racks and crates?
Cargo on a truck must be contained, immobilized or secured so it cannot shift enough to affect the vehicle, and tiedown systems are sized against set g-forces. The rules are in 49 CFR Part 393, Subpart I.
| Item | Figure or rule | Source | Notes |
|---|---|---|---|
| General rule | Cargo must be contained, immobilized or secured to prevent leaking, spilling, falling or shifting that affects stability or maneuverability | 49 CFR 393 subpart I | 393.100. Applies to trucks, truck tractors, semitrailers, full trailers and pole trailers. |
| Breaking-strength design forces | 0.8 g forward deceleration; 0.5 g rearward; 0.5 g lateral | 49 CFR 393.102 | 393.102(a)(1). Each condition applied separately. |
| Working load limit forces | 0.435 g forward deceleration; 0.5 g rearward; 0.25 g lateral | 49 CFR 393.102 | 393.102(a)(2). |
| Aggregate working load limit of tiedowns | At least one-half the weight of the article or group of articles | 49 CFR 393.106 | 393.106(d). Counting rules for direct and indirect tiedowns are in the section. |
| Equivalent securement in a sided vehicle | Cargo in contact with, or sufficiently close to, walls of adequate strength or other cargo so it cannot shift or tip | 49 CFR 393.102 | 393.102(c)(2). 393.106(b) lists the means: structures of adequate strength, dunnage or dunnage bags, shoring bars, tiedowns, or a combination. |
Related: Data center relocation equipment: what a move really uses
Who is liable for lost or damaged equipment, and how is a claim filed?
Under the Carmack Amendment a motor carrier is liable for the actual loss or injury to property it carries, unless liability was limited to a released value the shipper declared or agreed to in writing. A claim must be in writing, identify the shipment, assert liability and ask for a specific or determinable amount.
| Item | Figure or rule | Source | Notes |
|---|---|---|---|
| Carrier liability (Carmack Amendment) | Actual loss or injury to the property | 49 USC 14706 | 14706(a)(1). Runs against the receiving carrier, the delivering carrier, or the carrier on whose route the loss occurred. |
| Released value | Liability may be limited to a value declared by the shipper in writing or electronically, or set by written agreement, if reasonable | 49 USC 14706 | 14706(c)(1)(A). Check the declared or agreed value on the bill of lading before tender. |
| Minimum time to file a claim | Carrier may not allow less than 9 months | 49 USC 14706 | 14706(e)(1). The bill of lading may allow longer. |
| Minimum time to sue | Carrier may not allow less than 2 years from written disallowance | 49 USC 14706 | 14706(e)(1). |
| What makes a valid claim | Written; identifies the shipment; asserts liability; claims a specified or determinable amount | 49 CFR Part 370 | 370.3(b). Delivery-receipt notations or inspection reports alone are not a claim (370.3(c)). |
| Carrier acknowledgment | Within 30 days of receipt, unless paid or declined in writing in that time | 49 CFR Part 370 | 370.5. |
| Carrier disposition | Pay, decline or make a firm offer within 120 days; then written status every 60 days | 49 CFR Part 370 | 370.9. |
Related: Insurance, valuation and liability when infrastructure ships Certificates of insurance for data center moves
How are lithium and lead acid batteries in IT equipment regulated?
Lithium batteries are Class 9 hazardous materials classed under four UN numbers and governed in the U.S. by 49 CFR 173.185; standalone lithium ion batteries shipped by air must be at no more than 30 percent state of charge. Lead acid UPS batteries fall under 49 CFR 173.159, or 173.159a when non-spillable.
| Item | Figure or rule | Source | Notes |
|---|---|---|---|
| UN3480 | Lithium ion batteries (shipped on their own) | IATA Battery Guidance 2026 | Number also listed in the marking rules of 173.185. |
| UN3481 | Lithium ion batteries contained in equipment, or packed with equipment | IATA Battery Guidance 2026 | |
| UN3090 | Lithium metal batteries (shipped on their own) | IATA Battery Guidance 2026 | |
| UN3091 | Lithium metal batteries contained in equipment, or packed with equipment | IATA Battery Guidance 2026 | |
| Type testing | Each cell and battery type must pass UN Manual of Tests and Criteria, Part III, sub-section 38.3 | 49 CFR 173.185 | 173.185(a)(1). Manufacturers and distributors must make a test summary available (173.185(a)(3)). |
| Small lithium ion battery exception, size limit | 20 Wh per cell; 100 Wh per battery | 49 CFR 173.185 | 173.185(c)(1)(i). Larger cells and batteries do not qualify for this exception. |
| State of charge by air, U.S. rule | Lithium ion cells and batteries at no more than 30% of rated capacity (special provision A100) | 49 CFR 172.102 (A100) | "A" special provisions apply only to transport by aircraft. Higher charge needs PHMSA approval under Part 107, subpart H. |
| State of charge by air, standalone (IATA PI 965) | Not more than 30% of rated capacity; not on passenger aircraft without approval | IATA Battery Guidance 2026 | Above 30% only with approval of the State of Origin and State of the Operator (A331). Passenger aircraft per A201. |
| State of charge by air, packed with equipment (IATA PI 966) | Not more than 30% of rated capacity, from 1 January 2026 | IATA Battery Guidance 2026 | Section II applies the limit to batteries above 2.7 Wh. |
| State of charge by air, contained in equipment (IATA PI 967) | Recommended, not mandatory: 30% of rated capacity, or 25% indicated capacity | IATA Battery Guidance 2026 | |
| Lead acid (wet) batteries | Packaged to prevent dangerous heat, short circuits and terminal damage | 49 CFR 173.159 | 173.159(a). Exposed terminals protected with non-conductive caps, tape or similar. |
| Non-spillable lead acid batteries | Excepted from 173.159 packaging if securely packed or secured to pallets, protected from short circuits, and marked "NON-SPILLABLE" or "NON-SPILLABLE BATTERY" | 49 CFR 173.159a | 173.159a(c). No unabsorbed free-flowing liquid at 55 °C (131 °F) for the further exception in 173.159a(d). |
Related: Transporting UPS batteries under DOT and IATA rules
What temperature range does ASHRAE recommend for IT equipment?
ASHRAE TC 9.9 recommends an inlet dry-bulb temperature of 18 to 27 °C (64.4 to 80.6 °F) for all four air-cooled equipment classes, A1 to A4. It also limits how fast temperature may change: 20 °C in an hour and no more than 5 °C in any 15 minutes for most equipment.
| Item | Figure or rule | Source | Notes |
|---|---|---|---|
| Recommended dry-bulb range, classes A1 to A4 | 18 to 27 °C (64.4 to 80.6 °F) | ASHRAE TC 9.9 Reference Card | Facilities should be designed and operated to target the recommended range. Fahrenheit converted from the SI table. |
| Allowable dry-bulb range, class A1 | 15 to 32 °C (59 to 89.6 °F) | ASHRAE TC 9.9 Reference Card | Class A1 is typical of enterprise servers and storage in tightly controlled data centers. |
| Temperature change limit, most IT equipment | 20 °C in an hour, and no more than 5 °C in any 15-minute period | ASHRAE TC 9.9 Reference Card | Table note f. ASHRAE treats this as a change within a time window, not a rate. |
| Temperature change limit, tape | 5 °C in an hour | ASHRAE TC 9.9 Reference Card | Tape also needs 15 to 32 °C, 20 to 80% RH, maximum 22 °C dew point, no condensation (note c). |
| Power-off conditions (installed, not in use) | 5 to 45 °C; 8 to 80% RH | ASHRAE TC 9.9 Reference Card | Defined as equipment removed from its shipping container and installed but not running. It is not a shipping specification. |
| Humidity | All classes specified as noncondensing | ASHRAE TC 9.9 Reference Card | The reason cold equipment should acclimatize before power-on: a cold chassis in warm, humid air collects condensation. |
Related: Why hardware needs to acclimatize before power-on Climate controlled transportation for IT equipment
What do clear, purge and destroy mean under NIST SP 800-88?
NIST SP 800-88 Rev. 2 defines three sanitization methods: clear protects against simple, non-invasive recovery; purge makes recovery infeasible with state-of-the-art laboratory techniques; destroy does the same and leaves the media unable to store data. Degaussing applies only to magnetic media, never to SSDs.
| Item | Figure or rule | Source | Notes |
|---|---|---|---|
| Clear | Logical techniques on all user-addressable locations; protects against simple, non-invasive recovery using the normal device interface | NIST SP 800-88 Rev. 2 | Typically overwrite through standard read and write commands, or a factory reset where rewriting is not supported. |
| Purge | Physical or logical techniques that make recovery infeasible using state-of-the-art laboratory techniques | NIST SP 800-88 Rev. 2 | Cryptographic erase is a purge technique. |
| Destroy | Recovery infeasible using state-of-the-art laboratory techniques, and the media can no longer store data | NIST SP 800-88 Rev. 2 | Shred, disintegrate, pulverize, melt or incinerate. |
| Degaussing applicability | Magnetic tapes, removable magnetic disks and magnetic hard disk drives only; should not be used on flash media such as SSDs | NIST SP 800-88 Rev. 2 | Many degaussers lack the force for high-coercivity drives. Degaussing is not an approved destroy technique. |
| Certificate of sanitization: media details | Manufacturer, model, serial number, organizational property number (if any), media type, media source | NIST SP 800-88 Rev. 2 | Section 4.6. Sample form in Appendix C. |
| Certificate of sanitization: process details | Method (clear, purge, destroy), technique, tool and version, verification method | NIST SP 800-88 Rev. 2 | Pre-sanitization confidentiality category is optional. |
| Certificate of sanitization: verifier | Name, title, date, location, contact information and signature of the person verifying | NIST SP 800-88 Rev. 2 |
Related: Degaussing, shredding or crypto erase: choosing a method What a certificate of destruction must contain
Which seal and security standards apply to IT shipments?
ISO 17712 grades mechanical freight seals as I (indicative), S (security) or H (high security), and CBP's CTPAT program requires H-class seals on sealed member shipments. TAPA's Trucking Security Requirements set three certification levels for road carriers.
| Item | Figure or rule | Source | Notes |
|---|---|---|---|
| ISO 17712 seal classes | I = Indicative; S = Security; H = High Security | CBP CTPAT seal bulletin | Classification must be validated by independent labs accredited to ISO/IEC 17025. |
| CTPAT seal requirement | Sealable shipments sealed immediately after loading with a seal meeting the current ISO 17712 high-security standard | CTPAT Highway Carrier MSC | Criterion 6.2. Qualifying cable and bolt seals are both acceptable. |
| Seal inspection (VVTT) | View, Verify, Tug, Twist and turn | CBP CTPAT seal bulletin | View the seal and lock, verify the number, tug to confirm it is affixed, twist and turn to confirm it does not unscrew. |
| CTPAT participation | Voluntary, with no cost to join | CBP CTPAT | |
| TAPA TSR classification levels | Level 1 = Elevated; Level 2 = Moderate; Level 3 = Basic security protection | TAPA TSR 2023 | TSR 2023, section 6.1. Self-certification is available for Level 3 only. |
Related: Tamper-evident seals and GPS tracking on IT shipments Chain of custody form What a chain of custody form should record
Which NFPA standards govern IT rooms and their power?
Three NFPA documents matter most: NFPA 75 for fire protection of IT equipment and IT areas, NFPA 70 (the National Electrical Code) for electrical installation, and NFPA 110 for emergency and standby power systems. Your local authority having jurisdiction decides which editions apply.
| Item | Figure or rule | Source | Notes |
|---|---|---|---|
| NFPA 75 | Protection of IT equipment and IT equipment areas from fire and its effects: smoke, corrosion, heat and water | NFPA 75 | Current edition listed by NFPA: 2024. |
| NFPA 70 (NEC) | Safe electrical design, installation and inspection | NFPA 70 | Current edition listed by NFPA: 2026. Adoption and edition vary by state and locality. |
| NFPA 110 | Performance of emergency and standby power systems that supply alternate power when normal power fails | NFPA 110 | Covers power sources, transfer equipment, controls, supervisory and accessory equipment. Current edition listed by NFPA: 2025. |
What do RTO, RPO and FEMA flood zones mean for recovery planning?
NIST SP 800-34 defines the recovery time objective as the longest a system resource can stay unavailable before the impact becomes unacceptable, and the recovery point objective as the point in time to which data can be recovered. FEMA's high-risk flood areas are those with a 1 percent or greater chance of flooding in any year.
| Item | Figure or rule | Source | Notes |
|---|---|---|---|
| Maximum Tolerable Downtime (MTD) | Total outage time the system owner will accept for a mission or business process | NIST SP 800-34 Rev. 1 | Section 3.2.1. RTO must normally be shorter than MTD. |
| Recovery Time Objective (RTO) | Maximum time a system resource can be unavailable before unacceptable impact on other resources, processes and the MTD | NIST SP 800-34 Rev. 1 | |
| Recovery Point Objective (RPO) | Point in time before the outage to which data can be recovered; a measure of tolerable data loss | NIST SP 800-34 Rev. 1 | Not part of MTD. RPO is set and met by your IT team. |
| Base flood | 1 percent chance of being equalled or exceeded in any given year | 44 CFR 59.1 | |
| Special flood hazard area | Land subject to a 1 percent or greater annual chance of flooding; mapped as A or V zones | 44 CFR 59.1 | |
| Zone A / AE | Special flood hazard area; AE (and A1-30) where water surface elevations are determined, A where they are not | 44 CFR 64.3 | |
| Zone V / VE | Coastal high hazard area with velocity (wave action) from tidal floods | 44 CFR 64.3 | |
| Zones B, C and X | B/X: moderate flood hazard; C/X: minimal hazard | 44 CFR 64.3 | Zone D: undetermined but possible flood hazard. |
| Flood map lookup | Official flood maps by address | FEMA Map Service Center | Check both the primary site and the recovery site before staging equipment. |
Related: Disaster recovery logistics services DR site build-out and equipment staging
Which sources does this page cite?
Every figure above was read from one of these primary sources in October 2026. Regulations were checked against the eCFR (Electronic Code of Federal Regulations) and statute against the Cornell Legal Information Institute text of the U.S. Code. The ASHRAE figures come from the TC 9.9 reference card for the 2015 Thermal Guidelines; later editions exist, so confirm against the current ASHRAE publication.
- 49 CFR 395.3, Maximum driving time for property-carrying vehicles (eCFR)
- 23 CFR 658.17, Weight (eCFR)
- 49 CFR Part 393 Subpart I, Protection Against Shifting and Falling Cargo (eCFR)
- 49 CFR 393.102, Minimum performance criteria for cargo securement devices and systems (eCFR)
- 49 CFR 393.106, General requirements for securing articles of cargo (eCFR)
- 49 U.S.C. 14706, Liability of carriers under receipts and bills of lading (Cornell LII)
- 49 CFR Part 370, Investigation and voluntary disposition of loss and damage claims (eCFR)
- IATA Guidance Document for Lithium Batteries and Sodium Ion Batteries, revised for the 2026 regulations (67th Edition DGR)
- 49 CFR 173.185, Lithium cells and batteries (eCFR)
- 49 CFR 172.102, Special provisions (eCFR)
- 49 CFR 173.159, Batteries, wet (eCFR)
- 49 CFR 173.159a, Exceptions for non-spillable batteries (eCFR)
- ASHRAE TC 9.9 Reference Card, Equipment Thermal Guidelines for Data Processing Environments (2015 Thermal Guidelines, Table 2.1)
- NIST SP 800-88 Rev. 2, Guidelines for Media Sanitization (September 2025)
- CBP CTPAT Bulletin, Compliance With ISO's 17712 Standards for High Security Seals (April 2014)
- CBP CTPAT Minimum Security Criteria, Highway Carriers (March 2020)
- U.S. Customs and Border Protection, Customs Trade Partnership Against Terrorism (CTPAT)
- TAPA Trucking Security Requirements (TSR) 2023 Standard
- NFPA 75, Standard for the Fire Protection of Information Technology Equipment
- NFPA 70, National Electrical Code
- NFPA 110, Standard for Emergency and Standby Power Systems
- NIST SP 800-34 Rev. 1, Contingency Planning Guide for Federal Information Systems
- 44 CFR 59.1, National Flood Insurance Program definitions (eCFR)
- 44 CFR 64.3, Flood Insurance Maps (eCFR)
- FEMA Flood Map Service Center
- ASHRAE Technical Committee 9.9, Mission Critical Facilities, Data Centers, Technology Spaces and Electronic Equipment
DataTech Logistics handles the physical side of these rules: packing, transport, custody and installation of hardware. Data-side decisions such as recovery point objectives belong to your IT team, and any software wiping or cryptographic erase we coordinate is performed by a licensed contractor. Related tools: IT logistics tools.